Abstract

Rotation machines are one of the driving machines that are widely used in industrial factories because they are strong, reliable, easy to maintain and efficient. Installation of the machine with other equipment requires accuracy so that the axis between the two is truly an axis of "alignment". The importance of accurate alignment of the machine is the main reason for conducting this research, repairs that occur in the machine that require a shift between the motor and fan from their initial position need to be aligned. The method used is a rim and face dial indicator, measuring the axle on the face and rim hub that does not move and measuring the soft foot that occurs on the motor and aerator legs and measuring run out of the clutch at positions 0°, 90°, 180° and 270°. After getting the results of pre-alignment measurements and calculations, the HPFB A position of the aerator must be added with a shim for IB of 1,4 mm and OB of 1,99 mm. To shift the aerator the IB leg needs to be shifted to the left by 0,5 mm and the OB leg is shifted to the right by 1,1 mm. HPFB B aerator position must be added by shim for IB of 1,26 mm and OB of 1,86 mm. To shift the aerator, the IB leg needs to be shifted to the left by 0,45 mm and the OB leg is shifted to the right by 0,96 mm. HPFB C aerator position must be added with shim for IB of 1,4 mm and OB of 1,99 mm. To shift the aerator, the IB foot needs to be shifted to the left by 0,6 mm and the OB leg is shifted to the right by 1 mm.

References

D. D. Darmawan, A. Widodo, and I. Haryanto, “MISALIGNMENT KOPLING DENGAN ANALISIS SINYAL GETARAN KONDISI STATE MENGGNAKAN METODE REVERSE,” vol. 4, no. 2, pp. 197–206, 2016.

S. Soesanto and A. Farid, “Analisis Batas Toleransi Alignment Antara Poros Motor Listrik Dan Poros Fresh Water Cooling Pump Di Pt.Pindad (Persero),” Proton, vol. 10, no. 1, pp. 13–17, 2018, doi: 10.31328/jp.v10i1.802.

A. I. Tauvana, “Alignment Coupling Dengan Metode Double Dial indicator Rim and face,” Simetris J. Tek. Mesin, Elektro dan Ilmu Komput., vol. 9, no. 1, pp. 671–678, 2018, doi: 10.24176/simet.v9i1.2027.

Darto dan Sudjatmiko, “MEKANISME PROSES ALIGNMENT POROS MESIN ROTASI BERBANTUAN PERANGKAT LUNAK,” vol. 16, no. 1, pp. 11–20, 2015.

S. Syukri, “Analisis Penypangan Batas Toleransi Alignment Poros Motor Listrik dan Positive Pump DI PT. INDOLAKTO,” pp. 1–6, 2015.

I. N. Bagia and I. M. Parsa, “Motor-motor Listrk,” vol. 1, 2018.

Pln corporste university, “Fan, Blower dan Kompressor.”

H. Sonawan, “Perancangan Elemen Mesin Edisi Revisi.” Alfabeta Bandung, Bandung, 2014.

I. Standard, “Iso 10816-3,” vol. 1998, 2003.

firmansyah haris Munandar, “RESUME MASALAH DALAM VIBRASI,” 2016.

S. Adibroto, Buku Pedoman Praktis Alignment Mesin-mesin Rotasi, 1st ed. Jakarta, 2009.

Soenandar, Shaft Alignment. 2022.

PT PJB Kaltim teluk, “Kajian Time Delay Start HPFB.” .

Downloads

Published

2023-02-10

How to Cite

Suherna, S., Kelana, N. B. K. ., & Nurdin, A. (2023). Analisis Misalignment Pada Unit High Pressure Fluidized Bad Menggunakan Dial Indicator . IDENTIFIKASI, 8(2), 699–703. https://doi.org/10.36277/identifikasi.v8i2.251

Issue

Section

Jurnal Penelitian

Most read articles by the same author(s)

Obs.: This plugin requires at least one statistics/report plugin to be enabled. If your statistics plugins provide more than one metric then please also select a main metric on the admin's site settings page and/or on the journal manager's settings pages.